b deck weight per foot

Corrugated Metal Decking: B or N Deck - Pick Modules - Pallet Racks ResinDek? offers layout and design assistance for corrugated metal decking on b deck or N deck metal platforms, pick See the charts below, for allowable uniform total load span per square foot. Gauge, Thickness (in), weight (lb/ft2).

B Deck: Verco HSB-36 Roof Deck 1.5" B Deck Metaldeck.com b deck in stock. b deck is strong, light weight, economical, and easy to install and is the most common structural roof deck. Verco Normally b decking is used in short to medium span conditions ranging from 3 feet to 10 feet in distance.

Corrugated Steel Decking, B Deck - FS Industries Corrugated Steel decking, b deck, Mezzanine decking, ResinDek, Drill Screw Fasteners, Mezzanine Flooring, deck Panels, Galvanized b deck, and To calculate price of special lengths, multiply width (3) x special length (in feet) x price per square foot. . Depth, weight, Allowable Reaction, Section Modules, Moment

Metal Decking Design Guide - New Millennium Building Systems Coverage Thickness weight. I. Sp. Sn. (ksi). (in). (in). (psf). (in4/ft) (in3/ft) (in3/ft). 22. 33. 36. 0.0295. 1.63. 0.177. 0.189. 0.198. 20. 33. 36. 0.0358. 1.96. 0.213. 0.235. 0.247. 18. 33. 36. 0.0474. 2.57. 0.290. 0.315. 0.316. Gage. b, bA, bV deck.

Steel Deck Material and Design - Steel roof deck shall be United Steel deck b, F, N, J, H . Thickness .0295 .0358 .0474 .0598 .0295 .0358 .0474 .0295 .0358 .0474 .0598 .0358 .0418 .0474 .0598. weight, psf. 1.6 . Allowable end reaction per foot of deck width with 2” bearing for ASD and the factored nominal reaction for LRFD. 3.

Flexospan - Structural Steel Members - Steel C-Purlins & C-Girts b deck Wind, Snow, & weight Tables. Flexospan provides Wind load (lbs/sq ft) x .75 x girt spacing (ft) x wind coefficient (typically 1.1) = Allowable load/linear foot of girt. 20 psf x C Purlin and C Girt weight Table: weight per Linear foot.

OPD-0002-13 11 May 2017 (INSTALLED IN CONCRETE FILLED METAL b deck). CL1.20. EXPANSION .. b. FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET, A SEISMIC SEPARATION JOINT SHALL bE PROVIDED TO. DIVIDE THE 

floor deck catalog - ASC Steel Deck COMPOSITE deck. AND NON-COMPOSITE deck. FOR FLOOR AND ROOF deck APPLICATIONS. VERSION 1.0. This catalog is currently being updated. Please see IAPMO report for current engineering data. ER0329.

Steel Roof Deck - Steel Deck Institute weight of the steel deck. Plc. = concentrated construction and maintenance live load per unit width of deck section; 200 pounds on a 1 foot width (2.92 kN on a 1 meter width) b. Load and Resistance Factor Design. 1.2wdd + 1.4Plc. (Eq. 2.4.2).

1.5" "B" Wide Rib Roof Deck Cordeck Building Solutions 1.5" "b" Wide Rib Roof deck. #. Schematic. Product Specifications. Finish Quantity. Enter squares or dimensions. Squares. Number of Squares. or. Dimensions. Length ft. in. Number of Pieces. Product Downloads. 1.5 b Wide Rib Roof deck 

Canam - Steel Deck Catalogue (Canada) deep and are spaced at 152 mm (6 in.) center to center. The deck can be rolled to lengths from 1 800 mm. (6 ft.) to 12 200 mm (40 ft.). Nominal. Design. Overall. Section Modulus. Moment of Inertia. Type. Thickness. Thickness. Depth. weight.

Composite Steel Floor Deck - Slabs - Steel Deck Institute Panel end out of square shall not exceed 1/8 inch per foot of panel width (10 mm per m). 2.3 . b. The deflection of cantilevered deck as a form, as determined by slab thickness and self-weight of the steel deck, shall not exceed a/90, where.

Type B (Wide Rib) Roof Deck Corrugated Metal Panels deck Gage, Design Thickness In. weight Lbs. per Sq. Ft. “I” in. “Sp” in. “Sn” in. Ptd. Galv. 22. 0.0295. 1.70. 1.90. 0.165. 0.192. 0.198. 20. 0.0358. 2.07. 2.25. 0.214. 0.247. 0.256. 18. 0.0474. 2.80. 2.95. 0.308. 0.336. 0.347. 16. 0.0598. 3.30. 3.40.

sdi manual of construction with steel deck - Steel Deck Institute ay b e referred to as “b. ” deck. Sidelaps may b e flat adjustable or button punchable. A coustical deck will have p erforated w ebs. M . deck bundle weights for material to be .. as floor deck, but at least thirty pounds per square foot should be.

Corrugated Metals Products: B-Deck Roofing and Siding b-deck profile is usually used as a roofing product however, it has been supplied for siding and other architectural applications. Section, weight, Total Cross-Sectional Area A (in2), Allowable Stress Ma (lb-ft/ft), Moment of Inertia I (in4/ft), Section Modulus S (in3/ft), Allowable Moment Ma (lb-ft/ft). 18 Ga. 8.24. 2.70. 2.42.

weight charts - Groupe Robert weight CHARTS. FOR NORMAL ON SCALE, THE MAXIMUM WEIGTH per AXLE GROUP AND THE TOTAL MUST NOT EXCEED: JURISDICTION . 49,500 kg. Loading center point. 3,96 m /13 feet. Loading center point. 3,96 m /13 feet. b-TRAIN SEMI-TRAILER 2 AXLES –FLAT bED – SLIM PACK- DROP deck –.

Vulcraft Roof Catalog/REV2 - Civil, Environmental and Architectural deck. Design. weight (PSF). I. Sp. Sn. Fy. Type. Thick. Ptd. Galv. in4/ft in3/ft in3/ft. KSI. b24. 0.0239. 1.36. 1.46. 0.121. 0.120. 0.131 VERTICAL LOADS FOR TYPE 1.5b. Max. Allowable Total (Dead + Live) Uniform Load (PSF). No. of. deck. SDI Const. Span (ft.-in.) C. to C. . load carrying capacity per pound of steel utilized,.

Calculate Deck Load Capacity - Tributary Area - DecksGo The issues around deck load capacity is one I receive often from visitors asking how much weight they should design their deck for. The load that is placed on your deck is expressed in pounds per square foot (psf) and the total load or more appropriately, the design load, . Tributary area C is slightly larger than b and D. It is 6`long but its width extends from the midpoint of footing F1 to F2 and F2 to F3.

Weights of Building Materials – Pounds Per Square Foot [PSF] weights of building Materials – Pounds per Square foot [PSF]. CEILING. Acoustical fiber board (1). 1 20 gage metal deck (1). 2.5. 18 gage metal deck (1). 3 1" reinforced regular weight concrete. 12.5. 1" plain lightweight concrete (1). 8.